Secolink GSV4B Economy class alarm system with GSM/GPRS communicator and keypad KM20B Specs and Price in Kenya

Product Description
Secolink GSV4B Economy class alarm system with GSM/GPRS communicator and keypad KM20B:
Economy class alarm system for small real estate objects. Supports up to 7 zones (5 zones on control panels board and 2 on keypad). Kit includes control panel GSV4B with integrated GSM/GPRS communicator, keypad KM20B and fireproof, plastic case CAS6 with integrated transformer. Alarm system is available only as a kit.
Secolink GSV4B Economy class alarm system with GSM/GPRS communicator and keypad KM20B Specs
| Features | Secolink GSV4B |
| Description | Control panel with integrated GSM/GPRS module |
| In-built wired zones on board | 5 |
| Maximum wired zones | 7 |
| PGMÂ on board | 1 |
| Maximum PGM | 3 |
| User codes | 5 |
| Defaulting user code | Yes |
| Key switch zone | Yes |
| Partitions | 1 |
| System timers | 16 |
| Event log size | 256 (with keypad 512) |
| Data bus protocol | KRBUS |
| Reporting to CMS format | CID via GPRS |
| Total number of protocols, used for CMS reporting | E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
| Compatible with SG-SYSTEM II, III IP card | Yes |
| Alarm message for end user | GSM calls, SMS |
| Alarm message for end user by voice clip | Yes |
| Recordable audio alarm messages | Yes |
| Available language for SMS | English, National |
| Remote system control by Android or IPhone application | Yes |
| Zone speed (sensitivity) | 0.1 – 2.5 sec. |
| Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
| Arming mode | Away, Max Away, Night, Stay. |
| Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control;24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature. |
| Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night. |
| PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch. |
| PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification. |
| Rated voltage of power supply (AC) | ~20 V |
| Minimum AC voltage | ~16 V |
| Maximum AC voltage(Note: higher than ~22 V voltage can damage GSV4) | ~22 V |
| Maximum long term output current of GSV4(I+AUXÂ + I+BELLÂ + battery charge) | 0.7 A |
| Maximum current of slow blowing fuse used in primary AC | 250 mA |
| Maximum AC power consumption | <30 mA |
| Minimum voltage on +AUX, +BELL, outputs | 12 V |
| Maximum voltage on +AUX, +BELL, outputs | 13.9 V |
| Maximum current out of +AUX | 0.25 A |
| Maximum current out of +BELLÂ (without battery) | 0.2 A |
| Maximum current out of +BELLÂ (with battery) | 2 A |
| Short circuit, overload protection of +BELL, +AUX | electronic |
| Battery charge +BELL, +AUX current measurement | Yes |
| Failed (waste) backup battery disconnection | Yes |
| Maximum battery charging current | 0.25 A |
| Maximum current of fast blowing fuse used in battery | 3.15 A |
| GSV4 disconnects battery when it’s voltage less than | 9.5 V |
| Recommended backup power supply | 12 V, 7 Ah / 20 Hr |
| Operational compliance | EN50131, Grade2 |
| Overall dimensions W x H in mm | 120 x 64 |
| Environmental compliance | ROHS |
| Operating temperature | From -10oC to +50oC |
| Interface for control panel settings programming | USB |
| Interface for control panel firmware update | USB |
| Remote control panel settings programming | Yes, via www.alarmserver.net |
| Features | KM20B |
| Description | Alarm system keypad |
| On-Board zones | 2 |
| On-Board PGM | – |
| Ambient temperature measurement | – |
| LCD type | 2 rows, 16 symbols each |
| Keys in keypad | 20 |
| Programmable fast keys (F-Keys) | 32 |
| Data bus protocol | KRBUS |
| Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
| Maximum wiring distance to CP | 300 m |
| Power supply | 9 – 14 V |
| Voltage measurement on keypad | Yes |
| Current consumption | Backlight on 100 mA, baclight off < 50 mA. |
| On-Board sounder | Buzzer |
| Backlight color | Display = blue, keypad = yellow |
| Character set | Latin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian. |
| User interface type | Advanced, Simple, Baltic, Asian. |
| Overall dimensions W x H in mm | 115 x 95 |
| Environmental compliance | ROHS |
| Operating temperature | 0oC up to +50oC |
| Interface for keypad settings programming | USB |
| Interface for keypad firmware updating | USB |




Reviews