EVI 40000VA 36000W Tower Online 3 Phase UPS with DSP Control and Parallel Redundancy – EP-UPS40Y33OT
The EVI 40000VA 36000W Tower Online 3 Phase UPS is a high-capacity, industrial-grade power protection solution built for large-scale infrastructure, enterprise data centers, manufacturing environments, and mission-critical systems. Powered by advanced DSP-controlled double conversion technology and featuring true 3-phase input and output, this UPS delivers consistent, pure sine wave power with zero transfer time. With N+X parallel redundancy (up to 4 units), intelligent battery management, and support for both inbuilt and external batteries, it ensures reliable performance, flexibility, and continuous uptime for high-demand operations.
Product Features
True Online Double Conversion with DSP Control
Delivers pure sine wave output with zero transfer time, isolating critical loads from surges, spikes, brownouts, and other power disturbances. DSP (Digital Signal Processor) control ensures fast, accurate voltage regulation and improved system responsiveness.
3-Phase Input and Output
Ideal for large facilities and high-load applications, the three-phase architecture provides efficient, balanced power distribution and compatibility with industrial and enterprise-level equipment.
High Output Capacity with 0.9 Power Factor
Provides 36000W of usable power, maximizing real power delivery and supporting a wide range of modern, high-efficiency equipment.
N+X Parallel Redundancy (Supports up to 4 Units)
Supports up to 4 UPS units in parallel configuration for load sharing or full redundancy. N+X design provides automatic failover protection, maintaining continuity even during individual UPS failure.
Built-in and External Battery Support
Includes inbuilt batteries for standard backup time. External battery packs can be added to extend runtime based on critical load requirements.
Zero Output Transfer Time
Ensures seamless transition between mains and battery power with 0ms output transfer time—essential for sensitive systems and uptime-critical infrastructure.
Wide Input Voltage and Frequency Compatibility
Accepts input voltage from 208V to 478V AC and input frequency from 40Hz to 70Hz, ensuring stable performance even in challenging or unstable power conditions, including generator operation.
Low Input Harmonic Distortion with PFC
PFC (Power Factor Correction) technology keeps input current harmonic distortion under 3%, minimizing stress on upstream power infrastructure and reducing energy waste.
ECO Mode Operation
Offers energy-saving ECO mode during stable input power conditions, optimizing power usage without sacrificing protection.
Fully Digital Charging and Power Conversion
Utilizes advanced digital control over charging, rectifier, and inverter functions, ensuring accurate performance, higher efficiency, and better adaptability to varying loads.
Cold Start (DC Start) Capability
Allows the UPS to start from battery power when no utility power is available—critical for emergency startup or disaster recovery scenarios.
Intelligent Battery Charging Management
Monitors and manages battery charge cycles based on temperature and usage, helping extend battery life and prevent premature failure.
Emergency Power Off (EPO)
Includes EPO functionality for immediate shutdown of the UPS in emergency situations, meeting safety protocols and regulatory compliance.
7-Inch Touchscreen LCD Display
The large, full-color 7” touchscreen interface offers real-time status updates including input/output voltages, battery condition, alarms, and load information. Provides intuitive control and monitoring in a single panel.
Terminal-Based Input/Output Ports
Robust terminal ports allow secure connections for high-capacity systems and industrial installations requiring direct wiring.
Multiple Communication Interfaces
Standard communication includes USB, RS232, RS485, dry contact, and parallel port. Optional SNMP and relay cards support integration with building management systems, remote monitoring platforms, or automated alerts.
Product Specifications
- Capacity: 40000VA / 36000W
- UPS Type: Online Double Conversion
- Output Power Factor: 0.9
- Input Voltage Range: 208V – 478V AC
- Input Frequency Range: 40Hz – 70Hz
- Output Voltage: 380V / 400V / 415V AC (Three-Phase, Selectable)
- Output Waveform: Pure Sine Wave
- Output Transfer Time: 0 ms
- Input Current Harmonic Distortion: <3%
- Parallel Redundancy: N+X (Supports up to 4 units)
- Charging Technology: Fully Digital (Charger / Rectifier / Inverter)
- Battery Type: Inbuilt Batteries
- External Battery Pack: Optional
- Cold Start (DC Start): Supported
- ECO Mode: Supported
- EPO (Emergency Power Off): Supported
- Display: 7” Touch LCD (Real-Time System Information)
- Input/Output Interface: Terminal Ports
- Communication Ports:
- Standard: USB, RS232, RS485, Parallel Port, Dry Contact
- Optional: SNMP Card, Relay Card
- Intelligent Battery Management: Yes
- Operating Temperature: 0°C to 40°C
- Relative Humidity: 0% – 90% non-condensing
- Warranty: 2 years on UPS unit, 1 year on battery